IMC Networks iMcV-E1-Mux/4, SFP Bedienerhandbuch Seite 25

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 36
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 24
21
Troubleshooting
All iMcV-E1-Mux/4 units are shipped configured as Host units via DIP
Switch #1 = OFF. The Remote unit should be set to DIP Switch #1 = ON.
Be sure to confirm that the iMcV-E1-Mux/4 card is set correctly when used.
The fiber transport is independent of all other ports and should be
established first. If this is not possible, a physical fiber loopback can be used
for fiber port verification. A fiber loopback will cause all connected ports to
loop back their respected data.
If the fiber is not connected, all E1 ports will send the all-ones,
AIS
signal.
This can be physically looped back to verify E1 port operation.
Seitenansicht 24
1 2 ... 20 21 22 23 24 25 26 27 28 29 30 ... 35 36

Kommentare zu diesen Handbüchern

Keine Kommentare